from Seeed Studio $298 (Free shipping) http://www.seeedstudio.com/depot/preorder-imetry-p-1429.html
or via eBay $298 + $50 http://www.ebay.com/itm/iMetry-Geiger-counter-Spectrometry-Spectrometer-Spectroscopy-/261227046234
2cc Csi + Photo diode array (MPPC) instead of Photo diode
About 6000 cpm/ĘSv/h (similar to PM1703MO-1A/B)
The resolution might be a little less than Chappy detector and PM1703 MO-1A/B.
But we may be able to get better result using .
http://www.seeedstudio.com/wiki/IMetry_en
http://www.seeedstudio.com/wiki/IMetry_ja
http://www.nikiglass.jp/iMetry.html
Papers about MPPC
http://iopscience.iop.org/1748-0221/7/02/C02036/pdf/1748-0221_7_02_C02036.pdf
http://www-he.scphys.kyoto-u.ac.jp/theses/master/taguchi_mt.pdf
http://dpnc.unige.ch/users/blondel/ISS-2/MPPC_nakadaira.pdf
flc-hgf.desy.de/sites2009/site_flc-hgf/content/e14/e53/infoboxContent54/Valencia_MPPC.ppt
http://indico.cern.ch/getFile.py/access?contribId=60&sessionId=0&resId=0&materialId=slides&confId=164917
Hamamatsu MPPC
http://www.hamamatsu.com/jp/en/product/category/3100/4004/index.html
http://www.hamamatsu.com/jp/en/product/category/3100/4004/4114/S11064-050P/index.html
http://www.vertilon.com/spm.html
New Japanese site
http://imetry.wiki.fc2.com/
Betafite (Betaho stone???) Spectrum
http://imetry.wiki.fc2.com/wiki/%E3%83%99%E3%82%BF%E3%83%9B%E7%9F%B3?sid=d0a6b62ee06ad0c79f95c6c9ad89dabe
Th-232 Spectrum
http://imetry.wiki.fc2.com/wiki/%E3%83%99%E3%82%BF%E3%83%9B%E7%9F%B3?sid=d0a6b62ee06ad0c79f95c6c9ad89dabe
Thorium welding rod (Thorium Tungsten electroride) Spectrum
http://imetry.wiki.fc2.com/wiki/%E3%83%88%E3%83%AA%E3%82%A6%E3%83%A0%E5%85%A5%E3%82%8A%E3%82%BF%E3%83%B3%E3%82%B0%E3%82%B9%E3%83%86%E3%83%B3%E9%9B%BB%E6%A5%B5%E6%A3%92?sid=d0a6b62ee06ad0c79f95c6c9ad89dabe
Banana Spectrum
http://imetry.wiki.fc2.com/wiki/%E3%83%90%E3%83%8A%E3%83%8A?sid=d0a6b62ee06ad0c79f95c6c9ad89dabe
COK? (K-40) Spectrum
http://imetry.wiki.fc2.com/wiki/%E7%82%AD%E9%85%B8%E3%82%AB%E3%83%AA%E3%82%A6%E3%83%A0?sid=d0a6b62ee06ad0c79f95c6c9ad89dabe
Uranium glass spectrum
http://imetry.wiki.fc2.com/wiki/%E3%82%A6%E3%83%A9%E3%83%B3%E3%82%AC%E3%83%A9%E3%82%B9%E7%8E%89?sid=d0a6b62ee06ad0c79f95c6c9ad89dabe
Stone pavement in front of the train station
http://imetry.wiki.fc2.com/wiki/%E3%82%A6%E3%83%A9%E3%83%B3%E3%82%AC%E3%83%A9%E3%82%B9%E7%8E%89?sid=d0a6b62ee06ad0c79f95c6c9ad89dabe
Old site
http://w.livedoor.jp/imetry/
USB power (JA)
http://w.livedoor.jp/imetry/d/%c5%c5%b8%bb
Lead shield (JA)
http://w.livedoor.jp/imetry/d/%b1%f4%a4%cb%a4%e8%a4%eb%b4%c4%b6%ad%ca%fc%bc%cd%c0%fe%bc%d7%ca%c3
About $400 (in Japan) for 5 cm thick lead shield (with copper liner?)
http://w.livedoor.jp/imetry/d/%cb%dc%b3%ca%b4%c4%b6%ad%ca%fc%bc%cd%c0%fe%bc%d7%ca%c3%c8%a2
Temperature drift data (applicable to other small or big CsI detector?)
http://w.livedoor.jp/imetry/d/iMetry%a4%ce%b2%b9%c5%d9%a5%c9%a5%ea%a5%d5%a5%c8%ca%e4%c0%b5
Back ground in concrete building MEA_TIME 8 Hrs
Cs-137 5 min 31 sec
KCl (K-40) 2 hrs
Co-60 about 10 min
Cs-134 & Cs-137
Resolution isn't so great... PM1703MO-1A is probably better in this area (with 4cc CsI, instead of 2cc iMetry has)
- BUT, iMetry costs about 12 times LESS ! It's big !
Comparison
Chappy detector 3cc version about $600
CsI 12.7~12.7~19mm (3cc) about 4500cpm/ĘSv/h
- Some people are seeing separate peaks for Cs-137 and Cs-134 with Chappy detector. It depends on sound card, PC (USB power supply), etc.
PM1703MO-1A/B 4cc about $3,600
CsI 1.1 x 1.1 x 3.36 cm ? 6000cpm/ĘSv/h- With highly contaminated soil, it's easy to see separate peaks in PM1703MO-1A/B.
But it's expensive. (It comes with very helpful software, though)
Note: U235 lines are there for seeing the peak positions of it. It's not the indication that this spectrum is showing the presence of U235. Just to be sure that nobody starts to shout "Oh! They found U235 in Fukushima!!!!"
APD
http://beaune.in2p3.fr/sessions/kapusta.pdf
http://www.vertilon.com/apds.html
http://rmdinc.com/avalanche-photo-diodes/